Rockwell Automation DataMosaix Private Cloud – CISA
[[{“value”:”
1. EXECUTIVE SUMMARY
CVSS v4 8.7
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: DataMosaix Private Cloud
Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Missing Authorization, Incorrect Authorization
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to view user data or create, modify, or delete their own project.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Rockwell Automation reports that the following versions of DataMosaix Private Cloud are affected:
DataMosaix Private Cloud: Versions 7.07 and prior
3.2 Vulnerability Overview
3.2.1 Exposure of Sensitive Information to an Unauthorized Actor CWE-200
A data exposure vulnerability exists in DataMosaix Private Cloud. There are hardcoded links in the source code that lead to JSON files that can be reached without authentication. If exploited, a threat actor could view user data.
CVE-2024-7952 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2024-7952. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.2.2 Missing Authorization CWE-862
A vulnerability exists in DataMosaix Private Cloud that allows a threat actor to create a project and become the administrator for it. If exploited, a threat actor could create, modify, and delete their own project.
CVE-2024-7953 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-7953. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.3 Incorrect Authorization CWE-863
A vulnerability exists in DataMosaix Private Cloud that allows a threat actor to gain access to user’s projects. To exploit this vulnerability the threat actor must have basic user privileges. If exploited, the threat actor can modify and delete the project.
CVE-2024-7956 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N).
A CVSS v4 score has also been calculated for CVE-2024-7956. A base score of 7.6 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND
CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
Rockwell Automation reported these vulnerabilities to CISA.
4. MITIGATIONS
Rockwell Automation has addressed this issue in version v7.09 and encourages users to update to the newest available version. Rockwell Automation encourages users of the affected software to apply risk mitigations, if possible.
Rockwell Automation encourages users who are not able to upgrade to one of the corrected versions to apply security best practices, where possible.
For more information about this issue, please see the advisory on the Rockwell Automation security page.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY
October 10, 2024: Initial Publication
“}]] – Read More – All CISA Advisories